Specialized for CEMS, DGA-XP simultaneously measures NOx, SO₂, and O₂ using UV
DOAS (NOx, SO₂) and Zirconia (O₂)
| Measured Components | NOx, SO₂, O₂ |
| Measurement Principles | UV (NOx, SO₂) / Zirconia (O₂) |
| Measuring Ranges | NOx : Min 0~50 / Max 0~200 ppm |
| SO₂ : Min 0~50 / Max 0~200 ppm | |
| O₂ : 0-25 % | |
| Min. Measuring Unit | 0.1 ppm (NOx, SO₂), 0.01 vol% (O₂) |
| Zero Drift (2 hours) | 〈 ± 1% FS |
| Span Drift (2 hours) | 〈 ± 2% FS |
| Repeatability | 〈 ± 2% FS |
| Linearity | 〈 ± 2% FS |
| Response Time | < 5 seconds |
| Operating Temperature | -20 ~ +55 ℃ |
| Gas Temperature | < +200 °C |
| Analog Outputs | 3 Channel, 4 ~ 20 mA |
| Digital Outputs | 6 Channel |
| Digital Inputs | 3 Channel |
| Display & Input Device | 7" LCD Monitor (Touch Screen) |
| Interface | RS232,422,485 / LAN (Ethernet) / Hart |
| Dimensions | W300 x D420 x H413 mm |
| Weight | 22 kg |
| Enclosure Rating | IP66 |
| Voltage | 110/220 VAC, 50/60 Hz |
| Power Consumption | 500 W |
| Materials | SUS 316L or SUS 316Ti |
| Length | 0.5 ~ 2.5 m (Adjustable) |
| Measurement Section Length | 500 mm |
| Gas Flow Rate | > 1 m /s |
| Weight | 1.5 m : 25 kg |
| 2.0 m : 30 kg | |
| Purge Motor | Necessary |
| Temperature Sensor | PT 1000 |
| Dimensions | W550 x D350 x H850 mm |
| Weight | 15 kg |
| Voltage | P 480 VAC or 1P 220 VAC |
| Power Consumption | 1.0 kW ~ 1.5 kW |
| Analyzer | 0.2 ㎥/h |
Other products from this supplier
Browse: Manufacturer Directory Premium Suppliers Site Map
About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy
Copyright (c)1997-2026 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese
Business Registry Number: 120-86-03931 | Mall order sales Registration Number: 강남-5838